Open 24/7 · Heating & air for Sacramento & nearby Se habla español Open 24/7 · Sacramento · Se habla español CSLB #1016274 · (916) 247-6358
Costs & Buying

What Is SEER2? SEER vs. SEER2, EER2, HSPF2 and AFUE Explained

Every estimate for a new system is full of letters and numbers. Here’s what SEER2, EER2, HSPF2 and AFUE measure, what California requires, and when a higher number is worth paying for in a Sacramento summer.

Illustration: a new central air conditioner condenser on a raised gray pad beside a house with light siding, with insulated copper refrigerant lines and an electrical disconnect on the wall

JM Comfort can help: AC installation for homes in Sacramento and nearby. Licensed C-20 HVAC contractor, CSLB #1016274.

Efficiency ratings decide two things about a new system: whether it’s legal to install in California, and how much it costs to run through years of Sacramento summers. They also changed names in 2023, which is why an older quote or a neighbor’s advice may not match what you see today. This guide explains each rating in plain terms, gives the California minimums, and helps you decide how much efficiency to pay for in a new AC installation.

What is SEER2?

SEER2 stands for Seasonal Energy Efficiency Ratio 2, the federal rating for how efficiently a central air conditioner or heat pump cools over a typical season. The higher the number, the less electricity the system uses to cool your home.

The Department of Energy defines SEER as the total heat a system removes from your home during the cooling season divided by the electricity it uses over that same season. SEER2 is the same idea measured with an updated test. The 2023 federal efficiency standards are written in SEER2, so that’s the number on any system sold for installation today.

Here’s how the four ratings you’ll see on an estimate compare:

RatingWhat it measuresApplies toFederal minimum for a new system in California
SEER2Cooling efficiency over a whole seasonCentral ACs and heat pumps14.3 for split ACs under 45,000 Btu/h; 13.8 at 45,000 Btu/h and up; 14.3 for split heat pumps; 13.4 for single-package units
EER2Cooling efficiency at peak heat (95°F)Central ACs (regional rule)Split ACs: 11.7 under 45,000 Btu/h, 11.2 at 45,000 Btu/h and up, or 9.8 if rated 15.2 SEER2 or higher; single-package ACs: 10.6
HSPF2Heating efficiency over a whole seasonHeat pumps7.5 for split heat pumps; 6.7 for single-package
AFUEShare of the fuel that becomes heat in your homeFurnaces and boilers80% for most indoor gas furnaces

What’s the difference between SEER and SEER2?

SEER2 uses a tougher test than SEER, so the same equipment earns a lower number under SEER2. The Department of Energy created the new metrics because the test procedures changed, and it says SEER2, HSPF2 and EER2 are similar to the old ratings but not directly comparable.

The biggest change is airflow resistance. In a lab, a system pushes air against a set amount of “static pressure,” the resistance real ductwork creates. The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) says the new test “increases the external static pressure used when testing by up to five times,” which makes it a better match for real homes. AHRI says ratings under the new test have lower numerical values.

That’s why the federal minimum looks like it barely moved. AHRI notes the new standards rose only about 1 SEER from pre-2023 levels, yet it says products that just meet the new standard are approximately 7% more efficient. The practical rule: compare SEER2 to SEER2, and don’t compare a new SEER2 quote with an old SEER number.

What SEER rating do you need in Sacramento?

A new split-system central air conditioner installed in California must be at least 14.3 SEER2 if it’s under 45,000 Btu/h of cooling capacity, or at least 13.8 SEER2 if it’s 45,000 Btu/h or larger, and it must also meet an EER2 minimum. That’s because the Department of Energy puts California in its “hot-dry” Southwest region, along with Arizona, Nevada and New Mexico.

A few details matter when you shop:

  • Installation date, not manufacture date. In the Southwest, the standard for split-system air conditioners is based on the date of installation. A system installed on or after January 1, 2023 must meet the 2023 regional standard.
  • It’s the law for contractors. The Department of Energy says it’s illegal for a contractor to install a product that doesn’t meet the regional standards in the Southeast and Southwest.
  • Heat pumps follow the national standard. The regional rules apply only to air conditioners. Split-system heat pumps must be at least 14.3 SEER2 and 7.5 HSPF2 everywhere; single-package heat pumps, 13.4 SEER2 and 6.7 HSPF2.
  • Matched parts count. If only the outdoor unit is replaced on an older indoor coil, the Department of Energy’s examples say that outdoor unit must itself be certified to the Southwest standard. Ask your contractor to confirm the rating applies to the combination you’re buying.

Refrigerant rules changed too, so a replacement outdoor unit raises more than one question; see R-22, R-410A and R-454B explained. Capacity and efficiency are separate decisions: see what size AC you need.

What is EER2, and why does it matter in Sacramento?

EER2 (Energy Efficiency Ratio 2) measures how efficiently an air conditioner cools when it’s working its hardest: the Department of Energy describes EER as cooling capacity divided by power input at 95°F. California is one of the few places with a federal EER2 minimum, because the requirement applies only in the Southwest.

The Department of Energy says EER is “especially important in hot-dry climates, which experience more high-temperature days.” That describes Sacramento. NOAA’s 1991–2020 normals for Sacramento Executive Airport average about 76 days a year at 90°F or higher and 14 days at 100°F or higher. On those afternoons, EER2 tells you more about your system’s performance than the seasonal SEER2 average does.

Read the fine print on the rule. A split AC rated below 15.2 SEER2 must hit 11.7 EER2 (11.2 for 45,000 Btu/h and up), but a system rated 15.2 SEER2 or higher only has to reach 9.8 EER2. So a bigger SEER2 number doesn’t guarantee better peak-heat performance. When two quotes have similar SEER2 ratings, compare the EER2 numbers too.

What is HSPF2?

HSPF2 (Heating Seasonal Performance Factor 2) rates how efficiently a heat pump heats your home over a season. The Department of Energy says the higher the HSPF rating, the less electrical energy your heat pump uses to heat your home.

The federal minimum is 7.5 HSPF2 for a split-system heat pump. ENERGY STAR’s criteria for split-system heat pumps call for at least 7.8 HSPF2, along with 15.2 SEER2 and 11.0 EER2. Heating efficiency matters more here than many people expect: NOAA’s normals put Sacramento’s heating degree days at about 2,436 a year, against about 1,291 cooling degree days, even though the coldest nights are mild. The same normals average only about 15 nights a year at 32°F or below. If you’re deciding between a heat pump and gas heat, read heat pump vs. furnace and whether heat pumps work in Sacramento.

What is AFUE?

AFUE (Annual Fuel Utilization Efficiency) rates furnaces and boilers: the share of the fuel’s energy that becomes heat for your home over a year. An 80% AFUE furnace turns 80% of its fuel into heat for your home; the rest goes out the vent.

  • Federal minimum today. Non-weatherized gas furnaces, the kind installed indoors in most homes, must be at least 80% AFUE if made from November 19, 2015 onward. Weatherized (outdoor) gas furnaces must be at least 81%.
  • ENERGY STAR. Gas furnaces must be at least 95% AFUE to earn the ENERGY STAR in the U.S. South, a region that includes California. ENERGY STAR says certified gas furnaces there are up to 16 percent more efficient than standard models.
  • What’s coming. The federal regulation raises the minimum to 95% AFUE for non-weatherized gas furnaces made on or after December 18, 2028. That rule has been in court; a trade association reported in June 2026 that it remains in place while a federal appeals court reconsiders the case. Check its status before you plan around it.

Furnace troubles? Start with why a furnace stops working, or compare gas and electric furnaces.

Are new HVAC systems more efficient?

Yes. Federal minimums have risen over time, and the Department of Energy says the 2023 standards will lower utility bills because some types of central air conditioners have to be more efficient than before.

The bigger jump usually comes from replacing an old system with an efficient one. ENERGY STAR says high-efficiency heat pumps and air conditioners, installed correctly, can save up to 20 percent on heating and cooling costs, and suggests considering a replacement for a heat pump or air conditioner more than 10 years old. The words “installed correctly” matter. A high-SEER2 system on leaky ducts won’t deliver everything its rating suggests. See leaky ducts and duct sealing, and for what California’s energy code asks for when equipment is replaced, read HVAC permits and Title 24 in Sacramento.

Is a higher SEER2 rating worth it?

A higher SEER2 rating is worth it when the extra cost comes back through lower bills and rebates, which is more likely in a home that runs the AC hard through long, hot summers. The Department of Energy puts the trade-off plainly: a higher-rated air conditioner could be more expensive but will save you money on your electricity bill.

For what the whole project costs, see what a new HVAC system costs, and for questions to ask any contractor, see how to choose an HVAC company.

Why do Sacramento-area homeowners call JM Comfort?

JM Comfort is a locally owned heating and air conditioning contractor based in North Highlands, serving North Highlands, Sacramento and nearby communities. It’s a licensed C-20 HVAC contractor (CSLB #1016274), licensed since 2016 and bonded, with workers’ comp insurance on file; you can check the license on the CSLB website. JM Comfort handles AC installation, heat pumps and furnace installation for homes, along with repairs, tune-ups and ductwork, so you can compare efficiency levels with one local contractor before you decide.

Call (916) 247-6358 or request an AC installation estimate online and we’ll call you back.

Frequently asked questions

Is 14 SEER the same as 14.3 SEER2?

Not exactly, and that’s the point of the new name. The Department of Energy says SEER2, HSPF2 and EER2 ratings are similar to the old metrics but not directly comparable, because the test changed. Compare SEER2 to SEER2 when you’re shopping, and ask for the SEER2 number on every estimate.

Can I still buy an old 14 SEER air conditioner in California?

Only if it’s certified to the current Southwest standard. In the Southwest, the standard for split-system air conditioners is based on the installation date, so any split AC installed on or after January 1, 2023 must meet the regional SEER2 and EER2 minimums. The Department of Energy says it’s illegal for a contractor to install a product that doesn’t meet the Southwest standard.

Do I have to replace my old 10 SEER system?

No. The 2023 standards apply to new equipment being installed, not to systems already in your home. An older, low-efficiency system can keep running; it just costs more to operate than a new one. When it’s time, the repair-or-replace calculator can help you weigh it.

What ratings does an ENERGY STAR heat pump need?

ENERGY STAR’s criteria for split-system heat pumps call for at least 15.2 SEER2, 11.0 EER2 and 7.8 HSPF2. Those are above the federal minimums. As of November 2026, SMUD’s heat pump rebates also start at 15.2 SEER2. See SMUD HVAC rebates and tax credits.

When did SEER2 take effect?

January 1, 2023. The Department of Energy’s 2023 standards are written in SEER2, HSPF2 and EER2, and in the Southwest the air conditioner standard applies by installation date, so every split AC installed in California since then has had to meet the SEER2 and EER2 minimums. See how long HVAC systems last if you’re wondering when yours is due.

Does JM Comfort install new air conditioners and heat pumps?

Yes. JM Comfort, a licensed C-20 HVAC contractor (CSLB #1016274) based in North Highlands, installs central air conditioners, heat pumps and furnaces for homes in North Highlands, Sacramento and nearby communities. Call (916) 247-6358 or book online.

Sources

  1. 2023 Central Air Conditioner Standards FAQ (Guidance, issued October 5, 2022) (U.S. Department of Energy)
  2. 2023 Energy Efficiency Standards (AHRI)
  3. Heat Pump Equipment Key Product Criteria (ENERGY STAR)
  4. Furnaces Key Product Criteria (ENERGY STAR)
  5. Furnaces (ENERGY STAR)
  6. 10 CFR § 430.32 - Energy and water conservation standards and their compliance dates (Legal Information Institute, Cornell Law School)
  7. Supreme Court Vacates 95% Furnace Decision, Rule Remains in Place Until DC Circuit Reevaluates the Case (HARDI)
  8. When is it time to replace? (ENERGY STAR)
  9. Heating and cooling rebates (SMUD)
  10. U.S. Climate Normals 1991-2020, annual/seasonal: Sacramento Executive Airport, CA (USW00023232) (NOAA National Centers for Environmental Information)

Find this helpful? Add JM Comfort as a preferred source on Google.

Need a hand with your heating or cooling?

JM Comfort is a locally owned, licensed heating and air conditioning contractor (CSLB #1016274) serving the Sacramento area. Open 24/7: call or text any time, or book online and we’ll call you back.

Open 24/7 · Licensed C-20 HVAC contractor · CSLB #1016274 · (916) 247-6358

Call now Book service