Glossary
HVAC glossary, in plain words.
60 terms you’ll see on equipment labels, quotes and our guides, each explained the way we’d explain it at your kitchen table.
A
- A2L refrigerant (mildly flammable refrigerant)
- A refrigerant safety class that covers many of the newer, lower-GWP refrigerants. EPA lists R-454B and R-32 as A2L and describes them as mildly flammable. Why it matters: equipment is designed and installed around the refrigerant it uses, and EPA rules and industry standards don’t allow A2L refrigerants in systems that weren’t built for them, so handling them is a job for a certified technician only. Learn more →
- AFUE (Annual Fuel Utilization Efficiency)
- The percentage of a furnace’s fuel that becomes heat for your home over a typical year. A 90% AFUE furnace turns 90% of its fuel into heat; the other 10% escapes through the vent pipe and the cabinet. Why it matters: mid-efficiency gas furnaces run about 80% to 82% AFUE and condensing furnaces about 90% to 98%. AFUE doesn’t count the blower’s electricity or heat lost from leaky ducts. Learn more →
- Air filter (furnace filter)
- The filter at your return grille, furnace or air handler that catches dust and other particles before the air reaches the equipment. Filters are rated by MERV; a higher rating traps more small particles but adds resistance to airflow. Why it matters: a clogged filter chokes airflow, which can lead to frozen AC coils and furnace overheating shutdowns, so check it monthly and replace it as the filter or equipment maker directs. Learn more →
- Air handler (fan coil)
- The indoor cabinet that holds the blower and, on heat pump and many AC systems, the indoor coil; it pushes air through your ductwork for heating, cooling and ventilation. In a gas system, the furnace cabinet plays this role. Why it matters: when the blower, coil or drain inside it has a problem, the whole house feels it, even if the outdoor unit is running fine. Learn more →
- Auxiliary heat (aux heat, backup heat)
- Backup heat, usually electric heat strips in the air handler, that a heat pump system turns on by itself when the heat pump alone can’t keep up, such as on a very cold morning or during a defrost cycle. Your thermostat may show “Aux” while it runs. Why it matters: some aux heat is normal, but electric strip heat costs more to run than the heat pump, so aux heat that runs all the time is worth a service call. Learn more →
B
- Blower motor (indoor fan)
- The motor that spins the fan in your furnace or air handler, moving air across the heat exchanger or indoor coil and out through the ducts. It runs for both heating and cooling. Why it matters: if the blower stops, you lose airflow in every room; a failing blower can show up as weak airflow, new noises, or a furnace that overheats and shuts itself off. Learn more →
- BTU (British thermal unit)
- A unit of heat energy. Heating and cooling equipment is rated in BTU per hour (BTU/h), the amount of heat it can add to or remove from your home each hour; 12,000 BTU/h of cooling equals 1 ton. Why it matters: the BTU rating tells you a system’s size, and the right size comes from a load calculation for your house, not a rule of thumb. Learn more →
C
- Capacitor (run capacitor, start capacitor)
- A small electrical part, usually a metal can in the outdoor unit, that stores energy and gives the compressor and fan motors the boost they need to start and keep running. Capacitors wear out with age. Why it matters: a weak capacitor can leave the outdoor unit humming without starting, or the fan not spinning. It can hold a dangerous charge even with the power off, so testing and replacing it is a technician job. Learn more →
- Carbon monoxide (CO)
- A deadly, colorless, odorless gas made when fuel burns. In a home it can come from a malfunctioning furnace, water heater, range or fireplace, or from a portable generator. Early symptoms feel like the flu without a fever: headache, fatigue, shortness of breath, nausea and dizziness. If a CO alarm sounds, get everyone outside to fresh air and call 911. Why it matters: CPSC recommends battery-operated or battery-backup CO alarms on every level of the home and outside sleeping areas, and a professional inspection of your heating system every year (see what to do when a CO alarm goes off). Learn more →
- Compressor
- The pump in the outdoor unit that pressurizes refrigerant and drives it around the system; it’s what lets an AC or heat pump move heat out of your home, or into it on a heat pump in winter. Why it matters: the compressor is the heart of the system, and the wrong refrigerant charge can cause early component failure, so leaks and other problems that make it work harder are worth fixing before they cost you the compressor. Learn more →
- Condensate drain line (AC drain line)
- The pipe that carries water away from the drain pan under your indoor coil, and from a condensing furnace, to a floor drain, a small pump or outside. Your AC pulls moisture out of the air, and that water has to go somewhere. Why it matters: when the line clogs with algae or debris, you can get water around the unit, a wet filter, or a float switch that shuts the AC off. You can safely look at the line and pan for standing water; leave clearing a stubborn clog to a technician. Learn more →
- Condenser coil (outdoor coil)
- The coil and thin metal fins in the outdoor unit where refrigerant releases the heat it carried out of your home in cooling mode; on a heat pump in winter, the same coil collects heat from the outdoor air. A fan pulls air across it. Why it matters: dirt, leaves, grass clippings or shrubs crowding the unit keep it from shedding heat, which raises energy use and strains the compressor, so keep the area around it clear. Learn more →
- Condensing furnace (high-efficiency furnace)
- A gas furnace with a second heat exchanger that pulls extra heat out of the exhaust, cooling it until its water vapor condenses; these furnaces are rated about 90% to 98% AFUE. They vent exhaust straight outside through a dedicated pipe, and should have a second pipe bringing in outdoor air for combustion. Why it matters: they use less gas for the same heat, but they make water that needs a working condensate drain, and the venting has to be planned at installation. Learn more →
- Contactor
- An electrically controlled switch in the outdoor unit. When the thermostat calls for cooling, or for heat on a heat pump, a low-voltage signal closes the contactor and sends full power to the compressor and outdoor fan. Why it matters: a worn or pitted contactor can keep the outdoor unit from starting, make it buzz, or leave it running when it should be off. It carries high voltage, so it’s a technician repair. Learn more →
- Cracked heat exchanger
- A crack or hole in the metal wall that keeps a furnace’s flames and exhaust separate from the air blown into your home. It can let combustion gases, including carbon monoxide, get where they shouldn’t. Why it matters: technicians check the heat exchanger for cracks during furnace maintenance; if one is confirmed, talk through repair or replacement before running the furnace again, and keep working CO alarms on every level of the home. If a CO alarm sounds, get everyone outside to fresh air and call 911. If you smell gas, leave the home now and call 911 or your gas company from outside; don’t flip switches on the way out. Learn more →
D
- Defrost mode (defrost cycle)
- A normal heat pump routine in cold, damp weather: frost builds up on the outdoor coil, so the heat pump briefly reverses to warm the coil and melt it, then goes back to heating. You may see steam rising from the outdoor unit and hear a whoosh when it switches. Why it matters: steam and short defrosts are normal; an outdoor unit that stays caked in ice or never clears is not, and should be checked. Learn more →
- Dehumidifier
- A machine that removes moisture from the air, either a portable unit or a whole-house model ducted into your central system. Why it matters: in a dry Sacramento summer, a working AC usually handles indoor humidity on its own, so a dehumidifier earns its keep in damp spots, such as a crawlspace or a closed-up room, and during wet winter weather. Fix moisture sources first, such as a bare dirt crawlspace floor with no vapor barrier. Learn more →
- Dual fuel (dual-fuel heat pump)
- A system that pairs an electric heat pump with a gas or propane furnace as its backup heat. The heat pump handles cooling and most heating, and the furnace takes over when the heat pump can’t keep up on the coldest days. Why it matters: you get heat pump efficiency in mild weather and furnace heat in hard cold; the switchover point is set in the thermostat or control and can be tuned to your gas and electric rates. Learn more →
- Ductwork (ducts)
- The metal or flexible channels that carry air from your furnace or air handler to the rooms (supply ducts) and back again (return ducts), often through the attic, crawlspace or basement. Why it matters: DOE notes that duct losses can reach 30% or more when ducts are leaky, poorly insulated and run through an uninsulated attic or crawlspace, so testing, sealing and insulating them is worth asking about. Learn more →
E
- ECM motor (electronically commutated motor)
- A variable-speed blower motor that can ramp up and down instead of running only full-on or off, and uses less electricity than an older single-speed motor. Why it matters: an ECM blower can run at low speeds for long, steady cycles, but it has to work harder to push air through restrictive or poorly built ducts, which can wipe out the savings, so the ducts matter too.
- EER2 (Energy Efficiency Ratio 2)
- A cooling efficiency rating taken at one hot condition, 95°F outdoors, instead of averaged over a season like SEER2: cooling output in BTU/h divided by watts of power. The “2” means it comes from the newer DOE test used for ratings since January 1, 2023. Why it matters: EER2 shows how efficiently a system runs on the hottest afternoons, when your AC works hardest; ENERGY STAR split-system heat pumps must reach at least 11.0 EER2. Learn more →
- Emergency heat (EM heat)
- A thermostat setting on heat pump systems that shuts off the heat pump and runs only the backup heat: usually electric heat strips, or the furnace on a dual-fuel system. Unlike aux heat, which comes on by itself, you switch emergency heat on by hand. Why it matters: use it only when the heat pump itself has failed or the outdoor unit is damaged, for example after an ice storm, and call for service; heating on electric strips alone costs more than normal heat pump heating. Learn more →
- ENERGY STAR
- The government-backed efficiency label: products earn it by meeting strict energy efficiency guidelines set by EPA and the U.S. Department of Energy. For example, ENERGY STAR gas furnaces sold in the South must be rated at least 95% AFUE, and ENERGY STAR split-system heat pumps need at least 15.2 SEER2, 11.0 EER2 and 7.8 HSPF2. Why it matters: the label is a quick way to spot equipment that beats the federal minimums. Learn more →
- Evaporator coil (indoor coil)
- The coil in your air handler or on top of your furnace where cold refrigerant absorbs heat from the air blowing across it. It also pulls moisture out of the air, which drips into a drain pan. Why it matters: a dirty coil, a clogged filter or low refrigerant can make it freeze into a block of ice; if you see ice, turn the cooling off to let it melt and call for service. Learn more →
- Expansion valve (TXV, thermostatic expansion valve)
- A small valve at the indoor coil that drops the refrigerant’s pressure and meters how much flows into the coil; a thermostatic expansion valve (TXV) adjusts that flow as conditions change. Some systems use a fixed metering device instead. Why it matters: that pressure drop is what lets the refrigerant get cold enough to absorb heat, and a stuck or failing valve can cause weak cooling or a frozen coil.
F
- Flame sensor
- A thin metal rod that sits in the burner flame and tells the furnace’s control board the gas actually lit. If it doesn’t sense a flame, the control shuts the gas off for safety. Why it matters: a dirty or worn flame sensor can make a furnace light, run a few seconds, shut down and try again. It sits inside the burner compartment, so cleaning or replacing it is a technician job. Learn more →
- Flue (vent pipe)
- The pipe or chimney that carries a gas furnace’s exhaust, including carbon monoxide, out of your home. Older furnaces rely on natural draft, newer ones use an inducer fan, and condensing furnaces vent through a dedicated pipe straight outside. Why it matters: a blocked, corroded or disconnected flue can spill exhaust back into the house, so it should be checked at the yearly heating inspection, and outdoor vents should never be covered or blocked. If a CO alarm sounds, get everyone outside to fresh air and call 911. Learn more →
- Furnace
- The appliance that heats air, usually by burning natural gas or propane (some use electric heating elements), and blows it through your ducts with its blower. It often shares its cabinet and blower with your central AC. Why it matters: gas furnaces need a yearly professional inspection of the burners, heat exchanger and venting. If you smell gas, leave the home now and call 911 or your gas company from outside; don’t flip switches on the way out. More: what to do if you smell gas. Learn more →
H
- Heat exchanger
- The metal chamber or tubes in a furnace that get hot from the burner flames and pass that heat to the air blowing over them, while keeping the exhaust separate from your home’s air. Condensing furnaces add a second heat exchanger to capture extra heat from the exhaust. Why it matters: it’s the main barrier between combustion gases and the air you breathe, which is why technicians check it for cracks during furnace maintenance. Learn more →
- Heat pump
- An electric system that moves heat instead of making it: in summer it pulls heat out of your home like an air conditioner, and in winter a reversing valve runs the cycle backward to pull heat from the outdoor air into your home. Why it matters: one outdoor unit handles both heating and cooling, and because it transfers heat rather than generating it, it heats with less electricity than electric strip or baseboard heat. Many systems include backup heat for the coldest days. Learn more →
- HSPF2 (Heating Seasonal Performance Factor 2)
- A heat pump’s heating efficiency over a whole heating season: the heat it delivers divided by the electricity it uses, measured with DOE’s newer test required since January 1, 2023. Higher means less electricity to heat your home. Why it matters: the federal minimum for split-system heat pumps is 7.5 HSPF2, ENERGY STAR requires at least 7.8, and ENERGY STAR’s cold-climate designation requires at least 8.1 for ducted split systems. Learn more →
- Humidistat
- A control that senses indoor humidity and turns a dehumidifier or humidifier on and off to hold the level you set, the way a thermostat does for temperature. Some thermostats have one built in. Why it matters: it holds humidity in the range you choose without your having to watch it, running a whole-house humidifier when heated winter air gets too dry or a dehumidifier during damp spells. Learn more →
- HVAC (heating, ventilation and air conditioning)
- Short for heating, ventilation and air conditioning: the equipment that heats, cools, moves and filters the air in your home, including the furnace or heat pump, the AC, the ductwork and the thermostat. Why it matters: the parts work as one system, so a problem in one, like leaky ducts or a clogged filter, makes the rest run harder and cost more. Learn more →
I
- Ignitor (hot surface ignitor)
- The part that lights the gas burners in a modern furnace, usually a hot surface ignitor that glows bright orange, or a spark igniter. Older furnaces used a standing pilot light; DOE notes a furnace with a pilot light was probably installed before 1992. Why it matters: ignitors are fragile and wear out, and a failed one means the inducer runs but the burners never light. It sits in the burner compartment, so leave testing and replacing it to a technician. Learn more →
- Inducer motor (draft inducer)
- A small fan on a modern gas furnace that pulls combustion gases through the heat exchanger and pushes them out the flue. It’s usually the first thing you hear when the furnace starts. Why it matters: the steady draft it creates lowers the risk of exhaust spilling back into your home, and if it fails, a pressure switch keeps the burners from lighting. Learn more →
L
- Limit switch (high limit switch)
- A safety switch that shuts the furnace burners off if the inside of the furnace gets too hot, then lets them relight once it cools. Why it matters: a limit switch that keeps tripping is a warning sign, often of poor airflow from a clogged filter, blocked registers or a blower problem. Start by checking the filter, and never disable or work around a limit switch. Learn more →
- Line set (refrigerant lines)
- The pair of copper refrigerant tubes that connect the outdoor unit to the indoor coil: a larger, insulated suction line and a smaller liquid line. Why it matters: crushed tubing or missing insulation hurts efficiency, and leaks let refrigerant escape. When a system is replaced, the installer should tell you whether the existing lines can be reused with the new equipment and its refrigerant. Learn more →
- Load calculation (Manual J)
- A calculation of how much heat your home gains in summer and loses in winter, based on things like its insulation, windows, air leaks and which way it faces. ACCA’s Manual J is the standard method; Manual S is then used to choose equipment and Manual D to design ducts. Why it matters: sizing by rule of thumb has led to many oversized systems that short cycle and remove humidity poorly, so ask any contractor how the system they’re quoting was sized. Learn more →
M
- MERV (Minimum Efficiency Reporting Value)
- A 1-to-16 rating for how well an air filter catches particles, from ASHRAE’s Standard 52.2 test; the higher the number, the more small particles it traps. Filters rated MERV 13 and up must remove at least 50% of particles in the smallest size range tested. Why it matters: for people concerned about fine particles, EPA suggests at least MERV 13, or as high as your system’s fan and filter slot can handle, because a denser filter also restricts airflow; a technician can tell you what your system accommodates. Learn more →
- Mini-split (ductless heat pump)
- A ductless system: an outdoor unit connected by refrigerant tubing to one or more indoor units mounted on a wall or ceiling, each serving its own room or zone. Many are heat pumps, so they both heat and cool. Why it matters: with no ducts there are no duct losses, and each indoor unit can be set or turned off on its own, which suits additions, garages and rooms the central system doesn’t reach well. Learn more →
P
- Plenum
- The box-shaped section of ductwork attached directly to the furnace or air handler. The supply plenum collects conditioned air and feeds the supply ducts; the return plenum gathers air coming back from the return ducts. Why it matters: gaps where the plenum meets the equipment and main ducts waste air before it ever reaches a room, so those connections should be sealed. Learn more →
- Pressure switch
- A furnace safety switch that confirms the inducer fan is pulling exhaust through the furnace before the control lets the burners light. If the draft isn’t proven, for example because of a blocked vent, a clogged condensate drain on a high-efficiency furnace or a failing inducer, the furnace won’t fire. Why it matters: it keeps the furnace from running when exhaust can’t get out safely, so a tripping pressure switch needs a diagnosis, never a workaround. Learn more →
R
- R-22 (HCFC-22)
- An older refrigerant, often called “Freon,” used in many home AC systems and harmful to the ozone layer. U.S. production and import of R-22 ended January 1, 2020, but EPA lets existing R-22 systems keep running and be serviced with recovered, reclaimed or previously made R-22. Why it matters: R-22 supplies keep shrinking and prices may rise, R-410A isn’t an approved retrofit for R-22 systems, and a major R-22 repair is often the time to weigh replacement. The nameplate on your outdoor unit shows which refrigerant it uses. Learn more →
- R-410A
- The refrigerant that took over from R-22 in new home AC and heat pump systems. It doesn’t harm the ozone layer, but EPA lists its global warming potential (GWP) at 2,090. Why it matters: EPA rules now limit new home AC and heat pump systems to refrigerants with a GWP under 700, with allowances for some equipment made before 2025; California’s own rule bars refrigerants with a GWP of 750 or more in new home central AC and heat pump equipment from January 1, 2025; and the AIM Act requires an 85% phasedown of HFCs like R-410A from historic levels by 2036. You can keep using and repairing an existing R-410A system, including with R-410A replacement parts. Learn more →
- R-454B
- A lower-GWP refrigerant used in new home AC and heat pump systems; EPA lists its GWP at 470, compared with 2,090 for R-410A. EPA accepts it for new equipment only, with use conditions, and classes it as A2L, meaning mildly flammable. Why it matters: R-454B can’t be put into a system that wasn’t designed for it, such as an R-410A unit, and an existing R-410A system doesn’t have to be replaced just because newer refrigerants exist. Learn more →
- Refrigerant
- The fluid that carries heat in an AC or heat pump: it absorbs heat as it evaporates in one coil and gives it off as it condenses in the other, over and over in a sealed loop. It isn’t used up like fuel. Why it matters: a system that’s low on refrigerant has a leak, and the wrong charge can cut efficiency by 5% to 20%, so ask for the leak to be found. Only certified technicians should handle refrigerant, and it’s illegal to vent it on purpose. Learn more →
- Register (vent, supply grille)
- The grille in a floor, wall or ceiling where conditioned air comes out of the ducts into a room, usually with louvers you can adjust. Grilles that pull air back to the system are returns. Why it matters: keep registers open and clear of furniture, rugs and curtains. DOE advises against closing registers in unused rooms because it can cut airflow through the system and create pressure imbalances. Learn more →
- Return air (return vent, return grille)
- Air pulled from your rooms back to the furnace or air handler through return grilles and ducts, where it is filtered and heated or cooled again. Some homes have a return in each room; many have one or two large central returns, often in a hallway. Why it matters: a system can only push out as much air as it pulls back in, so blocked or too-small returns, or bedroom doors shut with no return inside, hurt comfort and make the equipment work harder. Learn more →
- Reversing valve
- The valve in a heat pump that switches the direction the refrigerant flows, so the same system can cool in summer and heat in winter. It also makes the switch during defrost. Why it matters: if a reversing valve sticks, a heat pump may heat but not cool, or cool but not heat; it’s part of the sealed refrigerant system, so repair is a technician job. Learn more →
S
- Section 608 certification (EPA 608 certification)
- The EPA certification that Section 608 of the Clean Air Act requires for technicians who maintain, service, repair or dispose of equipment that could release ozone-depleting refrigerants such as R-22. The exam has a core section plus sections for small appliances, high-pressure and low-pressure equipment. Why it matters: refrigerant work isn’t a homeowner task, and under Section 608 it’s illegal for anyone servicing or disposing of AC equipment to vent refrigerant on purpose, so ask any company you hire whether its technicians hold this certification. Learn more →
- SEER2 (Seasonal Energy Efficiency Ratio 2)
- A cooling efficiency rating for central ACs and heat pumps: the total heat removed over a cooling season divided by the electricity used, measured with DOE’s newer test in effect since January 1, 2023. Higher means less electricity for the same cooling. Why it matters: DOE puts California in its hot-dry Southwest region, where a split-system AC installed since 2023 must be at least 14.3 SEER2 under 45,000 BTU/h (13.8 SEER2 at or above that) and also meet an EER2 minimum for very hot days, while split heat pumps must be at least 14.3 SEER2 nationwide. SEER2 and old SEER numbers aren’t directly comparable. Learn more →
- Short cycling
- When a heating or cooling system turns on and off in short bursts, over and over, instead of running full, steady cycles. Causes include an oversized system, a clogged filter, a frozen coil, a refrigerant leak, a poorly placed thermostat, or a furnace overheating and tripping its limit switch. Why it matters: frequent cycling wastes energy, adds wear and raises maintenance costs, and in summer it leaves the air humid because the AC shuts off before it can remove moisture. Learn more →
- Single-stage / two-stage / variable-speed
- How many output levels a furnace, AC or heat pump has. Single-stage equipment is either fully on or off; two-stage equipment has a low and a high setting; variable-speed (modulating or inverter) equipment adjusts in small steps to match what the house needs. Why it matters: two-stage and variable-speed systems spend more time at lower, more efficient output, which helps keep temperature and humidity steady, and DOE notes oversizing is less of an issue with equipment that can modulate. They usually cost more to buy. Learn more →
- Split system
- The most common home setup: part of the system sits outdoors (the compressor and condenser coil) and part indoors (the air handler or furnace with the indoor coil), connected by refrigerant lines. A packaged unit puts everything in one cabinet instead. Why it matters: the indoor and outdoor parts are rated and certified as a matched pair, so replacing only one half can change efficiency and, in California and the other Southwest states, whether a new outdoor unit on an old indoor coil meets federal standards. Learn more →
- Static pressure (external static pressure)
- The resistance air meets as the blower pushes it through the filter, coil, ducts and registers, a bit like blood pressure for your duct system. Technicians measure it to see whether the system can move the air it was designed to move. Why it matters: high static pressure from a restrictive filter, a dirty coil, undersized or crushed ducts, or closed registers cuts airflow, which hurts comfort and efficiency and makes the blower work harder. Learn more →
- Supply air
- The heated or cooled air your system delivers to the rooms through the supply ducts and registers. Why it matters: weak supply airflow, or supply air that isn’t much warmer or cooler than the room, points to problems such as a dirty filter, leaky ducts, a frozen coil or a failing part. Heat pump supply air feels cooler than furnace air even when it’s working normally: DOE puts it at about 80°F to 115°F, versus 130°F to 140°F from a gas or oil furnace. Learn more →
T
- Thermostat
- The wall control that tells your heating and cooling system when to run, based on the temperature you set; programmable and smart models can follow a schedule. Most have a fan setting of Auto or On. Why it matters: DOE recommends Auto rather than On for the most efficient central AC operation, and notes that in humid climates a fan that keeps running after the compressor stops can put moisture from the coil back into the air. Before calling for service, check the batteries, the mode and the setpoint. Learn more →
- Ton (tonnage)
- A measure of cooling capacity, not weight: 1 ton equals 12,000 BTU per hour, so a 3-ton system can remove 36,000 BTU of heat per hour. On many outdoor units, two digits in the model number show the size, such as 24 for 24,000 BTU/h (2 tons). Why it matters: bigger isn’t better, because an oversized system short cycles and leaves the house clammy, so size should come from a load calculation. Learn more →
U
- UV light (UVGI, ultraviolet germicidal irradiation)
- An ultraviolet lamp installed in the ductwork or air handler, usually aimed at the indoor coil and drain pan, sold to kill or slow germs and mold. EPA’s technical review found typical home UV units don’t deliver enough UV to kill most airborne germs as air rushes past, but they can help keep coils and drain pans from growing mold and bacteria. Why it matters: UV doesn’t capture dust or allergens, so it’s an add-on to a good filter, never a replacement; choose lamps that don’t produce ozone, and plan on cleaning and replacing bulbs. Learn more →
Z
- Zoning
- Splitting a home into areas, such as upstairs and downstairs, that are heated and cooled to different temperatures, each with its own thermostat. It’s done with motorized dampers in the ducts, a separate system for each floor, or ductless units in individual rooms. Why it matters: zoning can fix a hot upstairs or a room that never gets comfortable, but dampers affect efficiency and airflow balance and have to be designed in; simply closing vents isn’t zoning and can strain the system. Learn more →
Sources
- Furnaces Key Product Criteria (ENERGY STAR)
- Heat Pump Equipment Key Product Criteria (ENERGY STAR)
- 2023 CAC Standards FAQ (central air conditioner and heat pump standards, issued October 5, 2022) (U.S. Department of Energy)
- Building America Best Practices Series Vol. 14: Energy Renovations - HVAC: A Guide for Contractors to Share with Homeowners (U.S. Department of Energy)
- Residential Air Conditioning and the Phaseout of HCFC-22: What You Need to Know (U.S. EPA)
- Frequent Questions on the Phasedown of Hydrofluorocarbons (U.S. EPA)
- Substitutes in Residential and Light Commercial Air Conditioning and Heat Pumps (U.S. EPA)
- Section 608 Technician Certification (U.S. EPA)
- Residential Air Cleaners: A Technical Summary (3rd Edition) (U.S. EPA)
- Carbon Monoxide Questions and Answers (U.S. Consumer Product Safety Commission)
- Air-conditioning Equipment (California Air Resources Board)